Добавить новость


News in English


Новости сегодня

Новости от TheMoneytizer

Pilot study of fractal dimension analysis of osteogenesis for bone substitute materials of Bio-Oss in lateral sinus augmentation

by Cai Wen, Qing Zhang

Background

Fractal dimension (FD) analysis has been proposed and validated in osseointegration-related research. The aim of this study was to evaluate the feasibility of FD analysis in the osteogenesis detection of bone substitute materials (BSMs) of Bio-Oss in maxillary lateral sinus augmentation.

Methods

Patients who received lateral maxillary sinus augmentation and underwent grafting with BSMs (Bio-Oss) were included in the study. The cross sections of the BSMs under cone-beam computed tomography (CBCT) at mesial, distal, and sagittal directions were obtained immediately after the graft (T0) and 6 months later (T1), and the obtained images were cropped to include only the BSMs. The FD analysis was performed, and the FD value was obtained by the method of box-counting. Paired t-tests and analysis of variance (ANOVA) were used, and p-values <0.05 was considered statistically significant.

Results

Twelve participants with 22 implants, which were inserted simultaneously after sinus augmentation, were included in this study. A total of 22 mesial, 22 distal, and 14 sagittal images were obtained after FD analysis. The mean FD value and standard deviation at T0 was 1.2860 ± 0.0896, while at T1, it was 1.2508±0.1023; thus, significant differences were detected (p = 0.022). However, the increasing or decreasing trend of FD value was not stable, and no significant difference was detected for FD values of mesial, distal, and sagittal images between T0 and T1. ANOVA indicated that no significant difference was detected among the FD values of mesial, distal, and sagittal images at any timepoint. Differences in FD values between the sexes were not significant either.

Conclusions

Since the FD analysis for the osteogenesis detection of BSMs in maxillary sinus augmentation indicated unstable trends of change, its feasibility is not reliable. The initially rough surface, self-degradation, and volume change of the BSMs during osteogenesis may be the reason for the variation in FD values.

Читайте на сайте


Smi24.net — ежеминутные новости с ежедневным архивом. Только у нас — все главные новости дня без политической цензуры. Абсолютно все точки зрения, трезвая аналитика, цивилизованные споры и обсуждения без взаимных обвинений и оскорблений. Помните, что не у всех точка зрения совпадает с Вашей. Уважайте мнение других, даже если Вы отстаиваете свой взгляд и свою позицию. Мы не навязываем Вам своё видение, мы даём Вам срез событий дня без цензуры и без купюр. Новости, какие они есть —онлайн с поминутным архивом по всем городам и регионам России, Украины, Белоруссии и Абхазии. Smi24.net — живые новости в живом эфире! Быстрый поиск от Smi24.net — это не только возможность первым узнать, но и преимущество сообщить срочные новости мгновенно на любом языке мира и быть услышанным тут же. В любую минуту Вы можете добавить свою новость - здесь.




Новости от наших партнёров в Вашем городе

Ria.city
Музыкальные новости
Новости России
Экология в России и мире
Спорт в России и мире
Moscow.media










Топ новостей на этот час

Rss.plus